SILVER AUTOMATION INSTRUMENTS LTD.

SX700 Temperature Controller

  • Resistance Thermometer Detector (RTD)

    Resistance Thermometer Detector (RTD)

    Basic Type RTDRTD with lead wireRTD with connection headRTD with connection head/nippleRTD with connection head/nipple/u...

  • Thermocouple

    Thermocouple

    Basic Type MI thermocoupleThermocouple with lead wireThermocouple with connection boxThermocouple with connection head/n...


Control Loop:1-2 loops

Program Quantity:
Max 10 suits programs;
Each suit contains max 30 segments.

High Accuracy:± (0.1% F.S)

Sampling Period:200msec


Application

Industry Furnace Control

Electric Furnace Control
Heating/Cooling
electric-furnace-control-1
heating-cooling
Scientific Experiments & Control

Double Loops Control
Temperature /Humid Control
double-loops-control
temperature-humid-control
Medicine & Semiconductor Production Application

Temp Control Disinfection
Reflow Oven Temp Control
temp-control-disinfection
reflow-oven-temp-control


Technical Specification
Construction

Installation Method

Panel mounted

Installation Angle

Horizontal tilted backwards 30 degree

Panel thickness

1-10mm

Outline Dimensions

96(W)×96(H)×93(D)

Net Weight

<0.8kg (not including accessories)


Power

Rated power supply:

220VAC

Allowed Voltage Range:

100VAC~240VAC

Rated Frequency:

50Hz

Consumption

≤3W


Input

Input Channel:

1-2 channels

Measuring Period

≤0.5 second

Signal types:

Direct Current (I), direct voltage (V), thermoucple and RTD.

Input types and Range

input-types-and-range

{Control Output}

Signal type:

4-20mA/0-10mA/0-20mA

Load Capacity:

600Ω or lower load resistance

Function:

1.Control output  2. Transmitting output

{Output Pulse Voltage}

Output Mode:

Time scale

Resolution:

10ms or 0.1% of the input value

Threshold Voltage:

12V or large,600Ω or higher load resistance

Close Voltage

o.1 V or smaller

{Relay}

Output Mode:

Time scale

Resolution:

200ms or 0.1% of the input value

Rating value of junction:

250 VAC(50/60Hz)3A  30VDC/3A(resistance load)

Analogue Input Board

Resolution:

16 bits

Sampling speed:

1 second

Signal terminal voltage:

Min -24V ,max +24V

Series-mode Rejection Voltage(50Hz)

5V signal:1.5V,

10V signal:1.5V,

20mV signal:50mV

100mV signal:150mV

Open circuit detection:

Open circuit of thermocouple, RTD, open circuit occurs when standard signal under 0.5V or 2mA.


Display

Display:

3.5” TFT color LCD (320×240 dots)

Unit:

7 letters or numbers

Status Display:

Title,alarm,USB,Time,etc

Display modes:

Control display, Function display (real curve, history  curve, back up, system log),configuration display

History Curve:

Display the recorded value, zoom 1/2/4/8/16/32

Display refresh Rate:

0.5 second


Alarm

Alarm types:

High alarm (H), Low alarm (L), Deviation High (DH), Deviation Low (DL)

Alarm Delay time:

0-10 second

Display

When alarm occurred, it will display on corresponding display ,and alarm icon on status bar

Alarm log:

Alarm log display happened alarms


Alarm Event Relay

Output points:

3 relays

Contact Capacity:

250VAC/3A;30VDC/3A (Resistance load)


Transportation and Storage

Environment Temp:

-10℃~60℃

Environment Humidity:

0%~95% (Non-condensate)


USB Function

Protocol:

Compatible USB 2.0 protocol

Terminal Port Quantity

1


Model Selection:

Model

Code

Function

SX701

 

Single loop control,30 segments *1

SX702

 

Double loop controls,30 segments for each loop *1

Addition

/T1

4~20mA output 1 channel *2

/A□

1~3

Relay 1~3 *3

/MT10

Each loop 10 groups process parameters, each process max 30 segments program

/C□

3

1channelRS485

 

33

2 channels RS485

 

4

Micro printer terminal port *4

/U

USB port


*1 :Signal inputs: K,S,T,B,E,J,R,N,WRE5-26,WRE3-25
*2: Signal outputs Options: 4~20mA, 0~20mA, 0~10mA,
*3: Relay 1 & relay 2 is normal open relay, relay 3 is normal close .
*4: Dedicated to micro Pinter.

Leave a Message Email Us

we will contact you within 24 hours.