Ultrasonic flow meter is for liquid flow measurement. Inline or portable ultrasonic flowmeter is available. In stock and...
Hydrostatic level transmitter;For water, oil or corrosive liquid level measurement;Range: 0-100 m level;4-20mA,HART ,Mod...
SHR-5620 Digital Display Volumetric Meter ,Produced by full-automatic chip mounter with surface mounting technology, has strong anti-jamming capability, and can collect liquid level data of regular and irregular tanks, and display and convert the data into tank volume, applicable to monitoring, control, and collection of process parameters.
Input |
|
||||
Input signal |
Current |
Voltage |
|||
Input impedance |
≤250Ω |
≥500KΩ |
|||
Maximum input current |
≤30mA |
|
|||
Maximum input voltage |
|
≤6V |
|||
Output |
|
||||
Output signal |
Current |
Voltage |
Relay |
24V distribution or feed |
|
Output load capability |
≤500Ω |
≥250 KΩ (Note: Please replace the module for higher load capacity) |
AC220V/3A (large) DC24V/3A (large) |
≤30mA |
|
Comprehensive parameter |
|||||
Accuracy |
0.2%FS±1bit |
||||
Setting mode |
Panel touch key setting; Parameter setting values locked; Permanent storage of the setting values under power-off |
||||
Display mode |
-1999~9999 measured value display, LBD display for working status |
||||
Working environment |
Ambient temperature: 0~50℃; relative humidity: ≤85%RH; far from strong corrosive gas |
||||
Power supply |
AC 100~240V (switch power), (50-60HZ); DC 20~29V (switch power) |
||||
Power |
≤5W |
||||
Frame |
Standard snap-on |
||||
Communication |
Standard MODBUS communication protocol; RS-485 communication distance up to 1 km, RS-232 communication distance up to 15 meters; note: While with communication function, the communication converter should be an active one. |