SILVER AUTOMATION INSTRUMENTS LTD.
Product Category

SX 6000 Paperless Recorder

SX 6000 Paperless Recorder

  • Thermocouple

    Thermocouple

    Basic Type MI thermocoupleThermocouple with lead wireThermocouple with connection boxThermocouple with connection head/n...

  • Temperature Transmitters

    Temperature Transmitters

    Temperature transmitters are an electrical transmitter that interfaces a temperature sensor (e.g. thermocouple, RTD) to ...

SX 6000 Paperless Recorder Overview

SX6000 color-screen paperless recorder has max 16-channel universal input function. Chartless Recorder can input the standard current, standard voltage, frequency, millivolt, thermocouple, thermal resistance and other signals. Paperless data recorder also has some other functions, including isolated power distribution output of sensors, relay alarm output, transmitter output, flow accumulation, temperature and pressure compensation, transfer storage of historical data, printing, Ethernet and remote communication.

As one of the professional paperless recorder manufacturers in China, SILVER AUTOMATION INSTRUMENTS provides high quality SX 6000 Paperless Recorder in various specification.

Functions & Features of SX6000 Paperless Data Recorder

System

• Paperless chart recorder manufacture using the latest large-scale integrated circuit.

• Using high-speed & high-performance 32-bit ARM microprocessor, paperless recorders can detect,record,display and alarm 16 channels signals simultaneously.

• 5.6 inch 320x 234 dot-matrix TFT high brightness and color graphic LCD, CCFL backlight, clear picture, brilliant color, and wide viewing angles. It is China low cost paperless recorders but with powerful functions.

• Fully isolated universal input, which can input a variety of signals. Paperless graphic recorder can be configured by software without jumper.

• New switching power supply, which can function properly within the range of 85VAC ~ 265 VAC.

• Integrated hardware real -time clock, which can run accurately in case of paperless chart recorder power down.

• Chartless Recorder provides isolated 24VDC power distribution for transmitter.

• Large capacity storage of FLASH memory chips to store historical data, which will never lose data in case of Paperless graphic recorder power-down.

• 12-way relay alarm outputs.(SX6016 max has 8 relay outputs)


Signals

• You can input a variety of standard signals: Standard current, standard voltage, frequency, millivolt, thermocouple, thermal resistance.

• Signal full- scale accuracy: ± 0.2%.

• Optoelectronic devices are used between channels and they are completely isolated.

• Providing standard 4-20mA for transmitter output.


Software

• Use password to protect configuration data.

• Easy  menu  configuration.  Paperless data recorder can configure freely and display the engineering tag number and engineering units.

• Engineering quantities display wide range of values. Paperless data recorder can show five digits: -9999~ 19999, and it also supports the display of vacuum scientific notation.

• Indicate the low low limit alarm, low limit alarm, high limit alarm, high high limit alarm of all channel simultaneously. Paperless graphic recorder can record up to recent 15 alarms.

• Each channel all supports flow accumulation function, and provides hourly report, 8-hour shift report,12-hour shift report, daily and monthly reports and other reports.

• Trend display mode can select horizontal trend or vertical trend.

• It can realize 12 groups temperature and pressure compensation. It can support orifice flow meter, vortex flow meters to realize compensation on steam, water, common gas.etc.

• 5 groups of trend combination are provided, and each group can be free to choose channel, free and the color of trends.

• It has a powerful T6 input method which is easy to operate. paperless recorder supports numbers, characters, special symbols, subscripts and superscripts input, etc.


Communication

• Standard serial communication interface for paperless chart recorder: RS-485 or RS-232C.

• Chartless Recorder supports the standard Modbus-RTU communication protocol, providing a variety of data types, such as the percentage, engineering quantities, accumulation and so on.In addition to supporting our company's data management software, it also supports some popular professional configuration software, such as the iFIX, MCGS, etc. but it is also China low cost paperless recorders.

• Use USB2.0 interface for transfer storage and backup of history records. Recorder paperless can support maximum 8G USB flash drives.

• Paperless chart recorder supports the FAT32 file system. Windows can automatically identify the backup data files without format conversion.

• It  can  connect  with  an  external  micro-printer,  so  you  can  manually  print  data  and  trends,  and automatically print real-time on a regular basis to meet the needs of the user to print on the field.

• Ethernet is available upon request from customers.


Display Screen for SX6000 Paperless Chart Recorder


 Overview


 Trend

Bar

- Overview -

In addition to displaying the test values, digital display can also display the tag number of channels, industrial units, alarm status, and accumulation information.

- Trend -

Horizontal trend to display values, combine freely the trends and trend colours.

- Bar -

It is convenient and visualized to use bar graph to display the test value. Meantime, it also displays the tag number of channels, industrial units and alarm state information.


History

- Alarm Summary-
Flow Display

- History -

It can re-appear the historical data stored in memory. Horizontal and vertical display types can be selected.

- Alarm Summary-

It can display the recent alarm time, and the time to remove the alarms.

- Flow Display -

It can display flow, temperature, pressure

On one display in the flow metering system, it can also display frequency, DP and density ,



Main Specifications of SX6000 PaperlessRecorder


Structure

Installation

Install the embedded instrument panel (vertical instrument panel)

Installation Angle

It is allowed a maximum 30 degrees tilt back in installation.

Dashboard thickness

1-10 mm

Dimensions:

144 (W) * 144 (H) * 220 (D) mm

Net Weight

Less than 2.6 kg (exclusive accessories)


Input section

Input points

1-12 channels,16 channels

Measuring period:

1 second

Input Type

Current, Voltage, Resistance, RTD, thermocouple, frequency


Input type and measuring range of SX6000 Paperless Recorder:


Input Type

Signal Type

Measuring range

Accuracy

Input Impedance


Current

4-20mA

4.00mA-20.00mA

±0.2 %

≤300Ω

10mA

0.00mA-10.00mA

±±0.2 %

≤300Ω



Voltage

1-5V

1.000-5.000V

±0.2 %

1MΩ

0-5V

0.000-5.000V

±0.2 %

1MΩ

0-10V

0.000-10.000V

±0.2 %

1MΩ

20mV

0.00-20.00 mV

±0.2 %

10MΩ

100mV

0.00-100 mV

±0.2 %

10MΩ

Resistance

400Ω

0.0-400.0Ω

±0.2 %

---



RTD

PT100

-200.0-650.0℃

±0.4℃

---

Cu50

-50.0-150.0℃

±0.4℃

---

Cu53

-50.0-150.0℃

±0.4℃

---

BA1

-200-650.0℃

±0.4℃

---

BA2

-200-650.0℃

±0.4℃

---







Thermocouple

S

-50-1768℃

±2℃

10MΩ

R

-50-1768℃

±2℃

10MΩ

B

500-1820℃

±2℃

10MΩ

K

-200-1372℃

±1℃

10MΩ

N

-200-1300℃

±1℃

10MΩ

E

-200-1000℃

±1℃

10MΩ

J

-200-1200℃

±1℃

10MΩ

T

-200-385℃

±1℃

10MΩ

WRE5-26

0-2310℃

±2℃

10MΩ

WRE3-25

0-2310℃

±2℃

10MΩ

F1

700-2000℃

±2℃

10MΩ

F2

700-2000℃

±2℃

10MΩ

Frequency

Fr

0-10000 Hz

±1Hz

---


Input Frequency

Low level:

0-2V

High level:

4-24 V


Analogy Input Board

Resolution ratio:

16 bit

sampling rate:

1second

Signal terminal withstand Voltage

Min:-24V DC, Max: 24VDC


Sensor Open Circuit Test:

RTD, Thermocouple open circuit

4-20mA input current less than 2mA

Others signals are not applied to.


Sensor Open Circuit Response:

RTD, Thermocouple open circuit

4-20mA       2 second

1-5V          2 second

RTD           4 second

Thermocouple   4 second



Display

Display:

Display colour

5.6-inch TFT color LCD display (320×234points)

256

Group number:

3 groups(1-12 channels),4 group (16 channels)

Each group can set 4 channels

Tag No.:

10 characters (Numbers)

Unit:

7 characters (Numbers)

Status display:

Display screen name, card status, alarm status, USB device status, circular display status, year, month, day, hour, minute, seconds

Display screen:




Overview display

Measuring data display(overview, digital display, bar graph display, the trend display),the historical trend display, the information display (alarm information, the accumulative reports),functional screen (data backup, printing)

Chartless Recorder  Display all the channels and alarm

Trend display:

Vertical or horizontal

History trend:

It can display the data stored in memory, it can zoom in 1/2/4/8/16/32 times

Alarm

Paperless graphic recordercan record 187 alarms



Temperature and Pressure compensation (Only available on SX6000F)

Measuring devices:

Orifice plate, Vortex flow meter(frequency)

Medium:

Steam, Water, gas

Steam temperature:

0-600℃

Steam pressure:

0.1-22Mpa

Steam status:

Automatically check saturated steam or overheated steam

Water temperature:

0-150℃

Water Pressure:

0.6-1.6Mpa

Gas compressibility coefficient:

Automatically check air, oxygen and nitrogen, others are manually set.

Vortex flow meter factor:

0.00000-999,999


Storage Function

External Storage for recorder paperless


  • Media: U disk
  • Format: FAT32
  • Mode: File
  • Capacity: 8GB


Internal Storage


  • Media: Flash memory
  • Format: Binary system
  • Mode: Continuous record
  • Capacity: 1-12 channels



Intervals

1 second

2 second

5 second

10 second

15 second

30 second

1 minute

2 minute

4 minute

Time

3 days

6 days

15 days

30 days

45 days

90 days

180 days

360 days

720 days

16 channels

Intervals

1 second

2 second

5 second

10 second

15 second

30 second

1 minute

2 minute

4 minute

Time

40 hours

3 days

8 days

16 days

24 days

48 days

96 days

192 days

384 days


Alarm

The number of alarms:

Each channel has max 4 alarms

alarm type:

High high alarm,high alarm,low low alarm,low alarm

Alarm delay time:

0-10s

Alarm output:

Alarm outputs to the internal relay

Display:

When alarm occurs, the corresponding screen displays the alarm status; the status display section displays the alarm icon.

Alarm information:

Alarm log in the alarm display


Clock

Clock:

Hardware clock(keep running after power off)

Range:

Year 2001-2099

Accuracy

±10ppm(0-50℃),exclude the delay(within 1s) caused by power on the meter




Power supply

Rated voltage:

220VAC

Allowable range:

100-240VAC

Rated Frequency:

50Hz

Consumption:

≤20W


24V DC Power supply for transmitter

Output Voltage:

24V DC

Max output current:

65mA DC (overload protect current: around 90mA)

Output points:

4 loops


Frequency Input Power Supply

Output Voltage:

12VDC,24V DC

Max output current:

30mA DC

Output points:

The same as frequency input


Transport and Storage Conditions for Paperless Recorder

Ambient temperature

-10-60℃

Ambient humidity

0%-95%( Non-condensate)


Standard Operation Conditions

Power supply voltage

220V AC

Power supply frequency

50Hz

Ambient temperature

0-50℃

Ambient humidity

0%-85%

Warm-up time

At least 30 minutes after power on

Installs position

Indoor


Model Selection of SX6000 Paperless recorder

1-12 Channels Input Model Selection

Model

Function

Code

Specification Code

Description

SX6001



Signal Input 1 channels

SX6002



Signal Input 2 channels

SX6003



Signal Input 3 channels

SX6004



Signal Input 4 channels

SX6005



Signal Input 5 channels

SX6006



Signal Input 6 channels

SX6007



Signal Input 7 channels

SX6008



Signal Input 8 channels

SX6009



Signal Input 9 channels

SX6010



Signal Input 10 channels

SX6011



Signal Input 11 channels

SX6012



Signal Input 12 channels

Function code

R


Record Function

F


Temperature & Pressure compensation




Additional Specification

/T□

1-4

4-20mA output 1-4 channels *1

/A□

1-12

Normal open contact output relays 1-12 channels

/C□

2

RS232

3

RS485

4

Micro printer interface *2

/U

USB interface

/L

Accumulation/ report

*1 SX6009-SX6016 no 4-20mA output

*2 Dedicated micro printer


16 Channels Paperless Graphic Recorder Input Model Selection

Model

Function

Code

Specification Code

Description

SX6016



Signal Input 16 channels

Function code

R


Record Function

F


Temperature & Pressure compensation



Additional Specification

/A8

Normal open contact output relays 1-12 channels


/C□

2

RS232

3

RS485

4

Micro printer interface *2

/U

USB interface

/L

Accumulation/ report


Custom Function for the Paperless chart recorder

Specification

Description

/FB□

1-12

Frequency input 8-40 channels, with 12 VDC power supply to transmitters *3

/FC□

1-12

Frequency input 8-40 channels, with 24 VDC power supply to transmitters *3

Leave a Message Email Us

we will contact you within 24 hours.

DMCA.com Protection Status