Coriolis Flow Meters for High-Pressure Chemical Injection


Chemical injection requires accurate flow measurement to maintain the correct dosage, particularly when chemicals are injected at very low flow rates or under high pressure. Choosing a suitable flow meter involves more than matching the pipe size. The required flow range, operating pressure and chemical compatibility all need to be considered.

The following case study looks at how we configured three customized SH-CMF Coriolis mass flow meters for dosing rates from 12 to 900 L/h at 6,000 PSI, why direct mass flow measurement suited the application, and how we supported the customer from sizing and drawing approval through documentation, delivery and remote setup.

The project at a glance

ItemDetail
IndustryOil and gas, upstream chemical injection
FluidsHYDRO 3X and RX-9025: corrosion inhibitor, oxygen scavenger, biocide
Line sizesDN3 (3 mm) and DN10 (10 mm)
Flow ranges12 to 60 L/h (0.2 to 1.0 L/min) on DN3; 150 to 900 L/h (2.5 to 15 L/min) on DN10
Operating pressure6,000 PSI (413 bar); meters rated to 42 MPa (6,090 PSI)
Operating temperature20 to 80 °C
Accuracy±0.2% of reading
Hazardous areaATEX certified, Zone 1
Outputs and communication4-20 mA and pulse; RS485 and HART
Quantity3 units: 2 × DN10, 1 × DN3
Order to shipment2 February 2026 to 2 April 2026, by air

The application: three chemicals into one 6,000 PSI line

The customer, a Sharjah-based instrumentation and chemical injection skid integrator, was building a dosing package for an upstream oil field. Three treatment chemicals had to be metered into the process line at 6,000 PSI: a corrosion inhibitor, an oxygen scavenger and a biocide. Two line sizes were involved. The low-dose additives ran through a 3 mm line at 12 to 60 litres per hour. The main inhibitor stream ran through a 10 mm line at 150 to 900 litres per hour.

The skid design already fixed two constraints that shaped meter selection. First, the pressure envelope was far beyond a standard process meter. Second, the three chemicals have different densities and viscosities, so any volumetric reading would need fluid-specific compensation before it could be trusted as a dose.

Key Challenges in High-Pressure Chemical Injection

Two factors shaped the flow meter selection for this application.

Different flow rates across the injection lines

The system handled three chemicals: corrosion inhibitor, oxygen scavenger and biocide. Their injection flow rates ranged from 12 to 900 L/h. The meters therefore needed to cover both low-flow and higher-flow applications, with suitable sizing for each flow range.

High operating pressure

The injection system operated at 6,000 PSI (413 bar). This required more than a standard pressure rating. Both the meter body and process connections had to be rated for the specified operating pressure.

The Solution: Customized SH-CMF Coriolis Flow Meters

To meet the different dosing requirements, we supplied three SH-CMF Coriolis mass flow meters in two sensor sizes: one DN3 and two DN10 units. The smaller DN3 meter handled flow rates of 12 to 60 L/h, while the DN10 meters covered 150 to 900 L/h. All three were configured for the 6,000 PSI application, with a customized pressure rating of 42 MPa.

The configuration also addressed the skid's installation and instrumentation requirements. Each meter featured a compact design with an integral display and totalizer, along with 4–20 mA and pulse outputs, RS485 and HART communication, and ATEX certification. The wetted parts were made of 316L stainless steel, and the process connections were customized to 1/2-inch NPT female.

Key Configuration

The following is the configuration code for the DN10 version:

SH-CMF-10-P4-H1-T1-O1/O2-C2/C3-E1-A2-B1-P2-M1-PC3

CodeConfiguration
10DN10 sensor, calibrated range 0–1,500 kg/h
P4Customized pressure rating: 42 MPa
H1Compact design with integral display and totalizer
T1Medium temperature rating: −50 to 150 °C
O1/O24–20 mA and pulse outputs
C2/C3RS485 and HART communication
E1ATEX explosion-proof certification
A2±0.2% accuracy
B1Transmitter ambient temperature: −20 to 50 °C
P2220 V AC power supply
M1316L stainless steel wetted parts
PC3Customized 1/2-inch NPT female process connection, rated to 42 MPa

The DN3 version used the same general configuration, with a 3 mm sensor and a calibrated range of 0–150 kg/h.

DN3 Coriolis flow meter for low flow chemical dosing

Customized DN3 Coriolis flow meters

DN10 compact high pressure Coriolis meter

Customized DN10 Coriolis flow meters

High-Pressure Design and Compact Installation

The operating pressure was 6,000 PSI (approximately 41.4 MPa), so the pressure-bearing section and process connections were specified for a 42 MPa rating (approximately 6,090 PSI). This provided a pressure rating above the required operating pressure. The 1/2-inch NPT female connections were also designed for the same pressure class and confirmed on the dimension drawings before production.

The compact design was another practical consideration for the skid integrator. The DN3 meter was approximately 368 mm tall, while the DN10 version was approximately 494 mm. With the display, totalizer and electronics integrated into the meter assembly, the customer did not need to allocate space for a separate remote transmitter housing.

DN3 Custom Coriolis Mass Flow Meter DrawingDN10 Custom Coriolis Mass Flow Meter Drawing

Our Work: From Meter Selection to Delivery and Support

The project took eight weeks from order confirmation to air shipment.We worked closely with the customer in meter selection, configuration, drawing approval, production, calibration and documentation, then continued to support the customer remotely via WhatsApp with setup, flow testing and totalizer adjustments.

1.Engineering and Meter Selection

We reviewed the flow requirements and selected one DN3 and two DN10 meters for the three injection lines.

2.Customization and Drawing Approval

We configured the meters for 42 MPa service with 1/2-inch NPT female connections. Separate drawings were prepared for the DN3 and DN10 versions and submitted for customer approval.

3.Production, Calibration and Documentation

All three meters were manufactured and factory-calibrated. The documentation package included factory calibration reports, a Certificate of Conformity (COC), Material Test Certificates (MTC) and ATEX documentation.

4.Delivery and Remote Technical Support

The meters were shipped by air. After delivery, we provided support via WhatsApp during flow testing and helped the customer change the totalizer display from cubic metres to litres.

switch the totalizer display from cubic metres to litres

Customer feedback

The customer shared positive feedback on both the flow measurement performance and our technical support. The following email excerpts and flow-trial video show their experience with the meters and our assistance during setup.

cutomer review about silver instruments coriolis flowmeters

Selecting a Coriolis Flow Meter for Chemical Injection

This project highlights several important points when selecting a Coriolis flow meter for high-pressure chemical injection:

  • Flow range and sensor size: Match the sensor to the actual injection rate. Different dosing lines may require different meter sizes, even within the same system.
  • Pressure rating: Check that both the meter body and process connections can handle the required operating pressure.
  • Fluid compatibility: Confirm the chemical composition and wetted-material compatibility before selecting the meter.
  • Measurement requirements: Consider whether direct mass flow measurement is needed for accurate chemical dosing.
  • Connections and instrumentation: Specify the process connection, output signals, communication protocol, power supply and hazardous-area approval.

Why Consider Silver Instruments for Your Coriolis Flow Meter?

The SH-CMF series offers several options for industrial applications, including:

  • Low-flow measurement: Multiple sensor sizes, including DN3 and DN10, for different dosing rates.
  • High-pressure customization: Special pressure ratings and process connections available for demanding applications.
  • Flexible configurations: Options for wetted materials, temperature ratings, outputs, communication and hazardous-area requirements.
  • Application support: Assistance with meter sizing, configuration, drawings, calibration and remote technical support.
  • An alternative to established brands: SH-CMF can be considered as an alternative to Micro Motion for suitable process measurement applications, subject to matching the flow range, pressure rating, materials, connections and installation dimensions.

For a replacement assessment, see our guide to Micro Motion Coriolis meter alternatives.

Looking for a Coriolis Flow Meter for Your Application?

Whether you are specifying a new chemical injection system or considering an alternative to an existing Micro Motion meter, send us your fluid details, flow range, operating pressure, process connection and current meter model.

Our team can review the requirements and recommend a suitable SH-CMF configuration.

Email: sales@silverinstruments.com
WhatsApp: +86 18936759191
Website: https://www.silverinstruments.com

FAQ

How do you select a Coriolis flow meter for low-flow chemical injection?
The sensor size should match the actual injection rate, not simply the pipe diameter. An oversized sensor may affect measurement performance near the lower end of its range. Check both the normal and maximum flow rates when sizing the meter.
Why use a Coriolis mass flow meter for chemical injection?
A Coriolis meter measures mass flow directly, making it suitable when chemical dosage is controlled by mass. It also measures density, allowing volume flow to be calculated without relying on a fixed density value.
What should be checked when selecting a flow meter for high-pressure chemical injection?
Check the pressure rating of the meter body and process connections, not just the nominal pressure of the sensor. Connection type, material strength and mechanical design must also suit the operating pressure.
Why is totalized flow important in chemical dosing applications?
Instantaneous flow shows the injection rate, while the totalizer records the amount delivered over time or during a dosing cycle. For small-volume dosing, displaying the total in litres may be more practical than using cubic metres.
What materials are available for Coriolis flow meter wetted parts?
Material options include 316L stainless steel, Hastelloy C-276, Hastelloy B3, Alloy 20, titanium and tantalum. The appropriate material depends on the chemical composition, concentration, temperature and corrosion conditions. Not every material is suitable for every chemical.
Email
sales@silverinstruments.com
WA
WhatsApp QR Scan to WhatsApp
Inquiry
Send a Quote